How it works
Cable loss is the datasheet attenuation at your frequency times the length: dB = dB per 100 m × metres ÷ 100. Connector losses you enter are added on top. The power at the far end is P × 10−dB/10, so 3 dB leaves half the power and 10 dB a tenth: 3 dB on 5 W leaves 2.51 W.
The figures come from each maker's own datasheet, as printed.2345678910111213 Between two printed frequencies the box draws a straight line on log–log axes, the way loss curves run; outside the printed range it does not guess, and you can type the loss from your own cable's sheet instead. Belden prints dB per 100 ft, converted here at 3.28084 ft to the metre.
The result is for a matched line: a high SWR adds loss on top. On receive the cable takes the same number of dB from the incoming signal. “RG-58” is a family name: two RG-58 cables from different makers can differ by a few dB per 100 m, so the box names the exact product.
Antenna lengths for your frequency: dipole antenna calculator.